Boston Unfinished Engineered Oak Flooring - ABCD Grade – 15/4 × 190 × 1900mm
Live flooring prices
Sign in to view pack and square metre pricing
Create a free customer account or sign in to see live prices, choose your pack or sample and use the flooring calculator.
Trade customer? Sign in to view your trade pricing. Apply for a trade account
Flooring delivery Usually 3–5 working days, subject to stock FREE
Flooring Click & Collect Usually ready in 3–5 working days FREE
Boston Unfinished Engineered Oak Flooring - ABCD Grade – 15/4 × 190 × 1900mm is part of our carefully selected real-wood flooring range, chosen for its construction, finish and natural character.
A real engineered oak plank floor selected for its stable construction, natural character and considered finish.
Supplied unfinished, the timber can be sanded and finished on site to suit the room and wider interior scheme.
Product specification
| Product code | 491 |
|---|---|
| Selected floor | 15/4 × 190 × 1900mm |
| Format | Plank |
| Construction | Engineered |
| Timber | Oak |
| Grade | Rustic |
| Pack coverage | 2.166m² per full pack |
| Price basis | Sold by the full pack, including VAT; equivalent price per square metre shown |
Natural timber and grading
Grading describes appearance rather than quality. Natural timber varies from board to board, so differences in tone, grain, knots, filler, sapwood and surface texture should be expected.
Wiltshire Wood Flooring Supplies advice
Engineered planks may be fully bonded or floated where the product and subfloor allow. We recommend confirming moisture readings, subfloor preparation and any underfloor-heating system before ordering.
-
ConstructionEngineered
-
Flooring formatPlank
-
Timber speciesOak
-
GradeRustic
-
Finish typeUnfinished
-
Colour toneMedium
-
Colour familyNatural
-
Surface characterSmooth
-
Thickness15 mm
-
Board width190 mm
-
Wear layer4 mm
-
Length typeFixed Length
-
Underfloor heatingYes
-
Pack coverage (m²)
These product-specific instructions summarise the current Lionvest Engineered Fitting Guidelines requirements. Fitting should be completed by an experienced wood-floor installer.
Before delivery and acclimatisation
- Use a competent wood-floor fitter and ensure the building is weather-tight with all wet trades complete.
- Maintain at least 18°C and 40–60% relative humidity; keep a written record of site and subfloor readings.
- Acclimatise sealed packs flat for at least 48 hours, supported clear of walls and direct heat.
Subfloor preparation and moisture
- The subfloor must be sound, clean, dry and free of paint, plaster, oil, dust and movement.
- Check flatness with a 2 m straightedge. Variation must not exceed 3 mm; level high or low areas before fitting.
- Measure and record subfloor moisture with the correct calibrated meter. Apply a compatible surface damp-proof membrane where readings or construction require it.
- Secure loose timber subfloors, countersink fixings and overlay uneven boards with suitable flooring-grade plywood without aligning joints.
- For full bonding, mineral subfloors must be below 65% RH; floated installations require below 75% RH. Timber subfloors must be within 2% moisture content of the flooring.
For more detail, read our engineered-floor subfloor preparation guide.
For boarded or suspended bases, read our timber subfloor preparation guide.
Fitting this floor
- Required method for this product: Fully bond or float using a compatible underlay and fully glued tongue-and-groove joints.
- For a floated tongue-and-groove floor, use the correct underlay and a continuous bead of D3 joint adhesive in both long and end grooves; do not spot-glue joints.
- For a bonded floor, use a compatible permanently flexible wood-floor adhesive and the specified notched trowel, checking adhesive transfer as work proceeds.
- Lay from at least three packs, inspect every board in good light and reject visible defects before fixing.
- Stagger end joints by at least 200 mm and avoid a repeating brick-bond pattern.
Use a system appropriate to the site and read our wood-floor adhesive guide.
Expansion, inspection and completion
- Provide at least a 10 mm continuous expansion gap at walls, door frames, pipes, hearths and fixed obstructions.
- Use movement breaks between rooms and wherever the manufacturer’s maximum uninterrupted span would be exceeded.
- Allow for cutting waste, grading and natural variation; mix boards across packs before fixing.
- Stop and contact Wiltshire Wood Flooring Supplies before fitting if the product, subfloor, site readings or proposed method do not match these requirements.
Compatibility
This engineered Lionvest floor is compatible with underfloor heating when the complete system is prepared and operated exactly as specified below.
Before installation
- Confirm that the flooring, UFH system, screed, controls, adhesive and underlay are mutually compatible before delivery.
- Commission, test and document the complete heating system before flooring is installed; repair screed cracks and hot or cold spots first.
- Measure and record the subfloor moisture at the correct test points. Do not fit until it meets both the floor and adhesive manufacturer’s limits.
- Maintain stable room humidity and use floor-temperature sensing. Rugs and furniture can create local heat build-up.
For low-profile systems, also read our UFH tray and overlay preparation guide.
Heating procedure and temperature limits
- All engineered Lionvest floors in this range are compatible; solid Lionvest floors are not.
- Full bonding is recommended over underfloor heating. Patterned floors must always be fully bonded.
- The wood surface temperature must never exceed 27°C and the room should remain at approximately 40–60% relative humidity.
- Run the manufacturer’s full heating-up and cooling-down programme before fitting, switch the system off for installation and restart gradually after the adhesive has cured.
- Increase the set point in small daily stages and avoid night-setback or other sudden temperature swings.
Important
- Keep the commissioning, moisture and temperature records with the installation paperwork.
- Do not fit if the UFH supplier, adhesive supplier and flooring requirements conflict; obtain a written project specification first.