Bedlington Solid Merbau Parquet - Natural – 18 × 70 × 280mm
Live flooring prices
Sign in to view pack and square metre pricing
Create a free customer account or sign in to see live prices, choose your pack or sample and use the flooring calculator.
Trade customer? Sign in to view your trade pricing. Apply for a trade account
Flooring delivery Usually 3–5 working days, subject to stock FREE
Flooring Click & Collect Usually ready in 3–5 working days FREE
Bedlington Solid Merbau Parquet - Natural – 18 × 70 × 280mm is part of our carefully selected real-wood flooring range, chosen for its construction, finish and natural character.
Made from solid merbau throughout, these parquet blocks can be arranged in classic patterns such as herringbone, double herringbone, basket weave or brick, depending on the selected size and design.
Supplied unfinished, the timber can be sanded and finished on site to suit the room and wider interior scheme.
Product specification
| Product code | 138 |
|---|---|
| Selected floor | 18 × 70 × 280mm |
| Format | Herringbone |
| Construction | Solid |
| Timber | Merbau |
| Grade | Select |
| Pack coverage | 0.588m² per full pack |
| Price basis | Sold by the full pack, including VAT; equivalent price per square metre shown |
Natural timber and grading
Grading describes appearance rather than quality. Natural timber varies from board to board, so differences in tone, grain, knots, filler, sapwood and surface texture should be expected.
Wiltshire Wood Flooring Supplies advice
Solid timber must be installed over a suitable, flat and dry subfloor and is not recommended over underfloor heating. Unfinished floors require professional sanding and finishing after installation.
-
ConstructionSolid
-
Flooring formatHerringbone
-
Timber speciesMerbau
-
GradeSelect
-
Finish typeUnfinished
-
Colour toneMedium
-
Colour familyNatural
-
Surface characterSmooth
-
Edge profileSquare Edge
-
Thickness18 mm
-
Board width70 mm
-
Length typeFixed Length
-
Pack coverage (m²)
These product-specific instructions summarise the current Lionvest Engineered Fitting Guidelines requirements. Fitting should be completed by an experienced wood-floor installer.
Before delivery and acclimatisation
- Use a competent wood-floor fitter and ensure the building is weather-tight with all wet trades complete.
- Maintain at least 18°C and 40–60% relative humidity; keep a written record of site and subfloor readings.
- Acclimatise sealed packs flat for at least 48 hours, supported clear of walls and direct heat.
Subfloor preparation and moisture
- The subfloor must be sound, clean, dry and free of paint, plaster, oil, dust and movement.
- Check flatness with a 2 m straightedge. Variation must not exceed 3 mm; level high or low areas before fitting.
- Measure and record subfloor moisture with the correct calibrated meter. Apply a compatible surface damp-proof membrane where readings or construction require it.
- Secure loose timber subfloors, countersink fixings and overlay uneven boards with suitable flooring-grade plywood without aligning joints.
- For full bonding, mineral subfloors must be below 65% RH; floated installations require below 75% RH. Timber subfloors must be within 2% moisture content of the flooring.
For more detail, read our engineered-floor subfloor preparation guide.
For boarded or suspended bases, read our timber subfloor preparation guide.
Fitting this floor
- Dry-lay and mark accurate centre and control lines before applying adhesive; check the pattern remains square throughout the room.
- Spread only as much flexible wood-floor adhesive as can be covered within its open time, using the manufacturer’s specified notched trowel.
- Press every block or board into a continuous adhesive bed and confirm full adhesive transfer. Patterned floors must not be floated.
- Keep the first rows aligned while the adhesive grabs, then re-check measurements frequently to prevent the pattern stepping.
- Clean adhesive from the face immediately with the approved cleaner and allow the full curing time before traffic or furniture.
Use a system appropriate to the site and read our wood-floor adhesive guide.
Expansion, inspection and completion
- Provide at least a 10 mm continuous expansion gap at walls, door frames, pipes, hearths and fixed obstructions.
- Use movement breaks between rooms and wherever the manufacturer’s maximum uninterrupted span would be exceeded.
- Allow for cutting waste, grading and natural variation; mix boards across packs before fixing.
- Stop and contact Wiltshire Wood Flooring Supplies before fitting if the product, subfloor, site readings or proposed method do not match these requirements.
Not suitable for underfloor heating
This is a solid timber floor. It must not be installed over an underfloor-heating system.
- Do not rely on adhesive, underlay or thermostat controls to make this solid product suitable.
- Choose an engineered alternative with confirmed underfloor-heating compatibility.
- Contact Wiltshire Wood Flooring Supplies before ordering if the heating system or floor construction is uncertain.